The Cryogen-free Measurement System. CryoAdvance, Inc.
|
LTLab, Inc. |
|
|
|
|
|
|
CryoMagn 1-40-12 (basic
model)
The cryostat CryoMagn 1-40-12 with superconducting magnet
designed for physical investigations in magnetic field up to 12 T at 4.2 K and
temperature region 0.3 - 300 K has extremely low helium consumption. The typical
applications are the studies of the Hall effect, superconductivity,
magneto-optics, spectroscopy and others.
The proposed design suggests location of the
superconducting magnet in a completely welded cryostat. Small opening for
inserts is compatible with the magnet bore. This minimizes the heat flow from
the top flange to the helium reservoir. The copper shield attached to the bottom
of the nitrogen reservoir and cooled by liquid nitrogen hangs over the cryostat
to its bottom.
|
The shielding reduces the helium boil-off and optimizes the consumption
of cryogenic liquids. The built-in liquid helium level gauge and removable
liquid helium transfer line provide the helium level monitoring and filling
services.
The highly reliable superconducting solenoid with attachable copper or
HTSC current leads is built by multifilament wire based on NbTi or
Nb3Sn superconductors. The resistor/diode protection circuit secures
the safety use of the superconducting solenoid. As an option, we supply a
superconducting switch to maintain the superconducting short-cut regime and the
electrical power supply for solenoid.
|
|
Basic parameters of the system
Central field at 4.2 K,
T
|
12
|
Homogeneity in a 10 mm
sphere near the center of solenoid
|
10-3
|
Maximum sweep rate,
T·sec-1
|
0.01
|
Maximum current,
A
|
250
|
Solenoid bore,
mm
|
40
|
Helium reservoir
capacity, L
|
25
|
Nitrogen reservoir
capacity, L
|
12
|
Liquid helium consumption
during cooling to 4.2 K, L
|
30
|
Liquid helium consumption
during operation, L/hour
|
0.3
|
Liquid helium consumption
with removed current leads, L/hour
|
0.15
|
Cryostat overall height,
mm
|
1350
|
Cryostat diameter,
mm
|
380
|
Total weight of cryostat,
kg
|
60
|
Complete
system
-
CryoMagn 1-40-12 cryostat.
-
Built-in helium level sensor.
-
Electronic unit for level monitoring.
-
Variable length liquid helium transfer
line.
Optionally
-
Variable temperature insert
INMAGN-115-1.2-He4 for temperature 1.2 - 300 K.
-
Temperature controller tSTAT310 with
Manostat.
-
Variable temperature insert
INMAGN-112-03-He3 for temperature 0.3 - 1.4 K.
-
Sample holder.
|
Additional
equipment
-
Liquid nitrogen level indicator.
-
Liquid nitrogen and helium storage vessels.
-
Additional sample holders.
-
Superconducting switches.
Key
benefits
|
|
CryoStor102
Application
fields:
|
- Embryos
- Oocytes
- Cell structures
- Sperm
- Blood
|
Liquid nitrogen storage system CryoStor102 is designed for
cryopreservation of pre-cooled biologic samples of various types. The system
guaranties a long-term storage of samples at liquid nitrogen temperature -196
°C. The system set consists of a number of liquid nitrogen tanks with 35 - 500 L
capacity and a level controller unit. The controller block enables the
monitoring of the liquid nitrogen level and samples temperature, as well as the
connection of automatic filling system.
|
The pre-cooled samples are placed in reservoirs in racks.
Each reservoir is equipped by a LN level measuring head. The LN control system
gives alarm signal when the LN level is less then 30% of maximal value. After
the alarm signal the automatic filling system starts. The controller unit can be
connected to the computer using the RS-232 interface. The controller unit
enables operation up to 8 liquid nitrogen storage
reservoirs.
|
Basic parameters of the system
Type of cryogenic
liquid
|
Liquid
nitrogen
|
Storage temperature,
°C
|
-196
|
Temperature gradients in
lower part of reservoirs, °C
|
1 ...
2
|
Accuracy of temperature
indication, °C
|
0.2
|
Temperature gradient
between the upper and lower part of reservoirs, °C
|
10
|
Reservoir volume,
L
|
35
|
Maximal vials number in
reservoir
|
250
|
Maximal number of
reservoirs used with one controller unit
|
8
|
Computer
interface
|
RS-232
|
Level
alarm
|
at 30 % of maximal
value
|
Alarm
type
|
Light/sound
|
Power supply,
V
|
~
220
|
Back-up system voltage,
V
|
12
|
Controller unit weight,
kg
|
2
|
Controller unit
dimensions, mm
|
300 х 240 х
50
|
Reservoir weight,
kg
|
21
|
Reservoir dimensions,
mm
|
Ø516 х
752
|
|
|
|
Copyright © 2006 CryoAdvance, Inc. All Rights Reserved |
|